Ȩ > Á¦Ç°¾È³» > Á¦Ç°»ó¼¼Á¤º¸ |
|
BCD (100kgf-500kgf) (CAS) |
|
|
|
Single point load cell, 100kgf - 500kgf BCD
Á¦Á¶»ç : CAS
°¡°Ý : ¹®ÀÇÇØÁÖ¼¼¿ä (ÀüÈ:031-618-3500)
|
|
|
BCD Single point load cell, 100kgf - 500kgf
¢Á FEATURES
Low cost
Off center compensated
Protection class IP65
¢Á Material
Anodized Aluminum
¢Á Mounting
Socket-head cap screw M8 1.25(10.9)
Tightening torque: 29Nm
¢Á Cable
Braided Shield 4-wire round cable
with PVC-Jacket
¢Á Maximum Platform Size
400 x 600mm (W L)
¢Á Ordering Information
BCD - XXXL
¦¬¦³
Capacity in kg
¡Ý Á¦Ç°»ç¾ç |
|
Max. capacity |
kgf |
100, 150, 250, 300, 500 |
Rated output
Zoro balance |
mV/ V
mV/ V |
2.0 ± 0.2
0 ± 0.1 |
Combined error
Repeatability
Creep for 30min.
Temperature effect on
Zero Value
Output value |
%
%
%
%/ 10¡É
%/ 10¡É
|
0.03
0.01
0.03
0.028
0.014 |
Excitation
Recommended
Maximum
Resistance
Input
Output
Insulation
|
V
V
Ω
Ω
MΩ |
10
15
400 ± 20
350 ± 3.5
£¾2,000 |
Compensated temperature range
Operating temperature range |
¡É
¡É |
-10 to +40
-20 to +70 |
|
|
|
|